End-to-End Support from Continuous R&D Spectral Logging to QA & FA Inline Automated Inspection
TAMTEC GRANATUS
Multi-Vendor Spectral, Optical Property, Colorimetry & FA Inspection Software
From real-time spectral acquisition and intensity calibration to optical filter transmittance, optical density (OD), cut-on / cut-off wavelength (wavelength at specified %T or OD), object color and light source CRI evaluation, long-term drift logging, barcode-linked inspection reports, and PLC-integrated inline pass/fail judgment — all in a single software environment.
Multi-Vendor USB Spectrometer Support
Use your existing spectrometer assets — or request a complete turnkey package including spectrometer, light source, and optical fixtures
Continuous Time-Series Logging & Local API / AI (MCP)
Built-in timer logging plus automated experiment control via standard Python / LabVIEW / C# scripts
HTML Inspection Reports & Direct PLC Inline Link
Barcode recipe switching, A4 HTML report generation, and SLMP / Modbus TCP communication

TAMTEC GRANATUS Main Screen (Standard 2-Stage View: Upper Raw A/D Monitor, Lower Calibrated Spectrum & Optical Evaluation Markers, Right Pass/Fail Judgment Pane. Note: All software menus, dialogs, and HTML inspection reports switch to full English in English UI mode.)
①Dual Cockpit Bar
Instant access to exposure, averaging, calibration mode, lot logging, and FA status
②A/D Raw Waveform & Saturation Guard
Continuous monitoring of raw A/D counts, saturation threshold, and Dark/Ref waveforms
③Calibrated Spectrum & Optical Markers
Highlights evaluation bands and key feature points directly on the calibrated spectrum
④Real-Time Judgment & Metrics List
Displays live values, LSL/USL limits, and overall JUDGE: PASS / FAIL status at a glance
* Evaluate all features with your own spectrometer (including compatibility checks & technical consultation)
Key Challenges Solved in Spectral Measurement & Inspection
Addresses common bottlenecks and automation requirements across R&D, quality assurance, and production engineering:
Eliminating manual CSV imports into spreadsheets every time to calculate transmittance, OD, and cut-on / cut-off wavelengths
Automatically recording and plotting LED or halogen light source warm-up behavior and multi-hour intensity or CCT drift
Preventing human error from manual file naming and manual transcription into outgoing inspection reports
Performing real-time pass/fail judgment based on product specifications such as Edge Transition Width (Δλ) from 80% transmittance to OD 3.0
Minimizing custom software development cost and lead time when integrating spectrometers with PLCs and barcode readers on production lines
Consulting on the optimal combination of spectrometer, light source, and optical fiber fixtures for specific measurement samples
TAMTEC GRANATUS meets all of these requirements from R&D to quality assurance and mass-production lines out of the box.
5 Practical Application Scenarios
Explore five representative workflows tailored to your measurement targets and operational phases.
Optical Filter & Thin-Film Coating Evaluation and Outgoing Inspection
Eliminate spreadsheet post-processing with real-time calculation and JUDGE: PASS/FAIL evaluation of specification metrics
Calculates key optical characteristics required by product specifications in real time for bandpass filters, IR-cut filters, dichroic mirrors, anti-reflective (AR) coatings, and ND filters.
Key Optical Evaluation Functions
●Low-Transmittance & High-OD Blocking Band Evaluation: Mean then OD (Mean->OD)
Supports the 'Mean then OD (Mean->OD)' method, which averages linear transmittance across a wavelength band before applying the logarithmic transform (-log₁₀). By canceling out random zero-level dark noise fluctuations prior to conversion, this method minimizes calculation bias caused by negative-value clipping and logarithmic nonlinearity—delivering reliable band-average OD even in high-attenuation blocking regions near the spectrometer's detection limit (OD 3 and above).
●Sub-Pixel Wavelength Calculation: WL at Target Intensity (YFix)
Calculates the exact cut-on or cut-off wavelength crossing a specified threshold (such as T = 50% or OD = 3.0) using sub-pixel linear interpolation between adjacent detector pixels.
●Direct Slope Width Across Linear (%) and Log (OD) Scales: Edge Transition Width (Δλ)
Directly register and evaluate specifications combining linear and logarithmic scales — such as requiring the Edge Transition Width (Δλ) from 80% transmittance to blocking OD 3.0 to be 15.0 nm or less.
●Stable Center Wavelength & FWHM on Flat-Top and Rippled Spectra
Suppresses shot-to-shot center wavelength jitter on flat-top bandpass filters or spectra with interference ripples using Peak / Valley Detection (Arithmetic Avg AA in wavelength space or Harmonic Avg HA symmetric in wavenumber/photon-energy space) from left/right crossings at a specified slice depth. Also supports FWHM / Center WL (CWL) calculation on sloped backgrounds.
●Fundamental Spectral Preprocessing & External Master CSV Reference
Includes auto-exposure, independent time averaging (Averaging) and spatial moving average (Smoothing), and three calibration modes: Uncorrected Raw Mode (Raw [cnt] / exposure-normalized [cnt/ms]), Relative Ratio [%], and 2-stage spectral-sensitivity-corrected Relative Irradiance. Previously saved golden-sample CSVs can also be locked as fixed references.
Optical Filter & Thin-Film Coating Evaluation Metrics Map (Wavelength Band, Mean then OD, WL at Target Intensity YFix, Edge Transition Width Δλ, FWHM / Center WL)
Light Source (LED, Halogen, Laser) Warm-Up & Long-Term Stability Testing
Continuously log and quantify output drift and wavelength shift from turn-on across multiple hours without coding
Record and evaluate warm-up time to thermal equilibrium and long-term intensity, peak wavelength, or color temperature drift for white LEDs, halogen lamps, deuterium (D₂) lamps, and excitation lasers without writing any code.
Key Time-Series Logging & Stability Analysis Functions
●Automated Interval Continuous Logging
Logs automatically at intervals from 0.1 s to 3600 s for a specified duration or shot count. Optional saturation-skip protection allows long-term runs to continue uninterrupted even if transient ambient light causes temporary sensor saturation on a single frame.
●Trapezoidal Band Integration Accounting for Non-Uniform Grating Pixel Pitch
Tracks not only simple pixel averages but also the wavelength-weighted band integral (∫Y(λ)dλ, proportional to total radiant energy) accounting for per-pixel wavelength width [nm].
●Time-Series Trend Chart with Relative Delta Mode
Switch the trend chart vertical axis to [Δ Change] (relative to the initial record = 0) to overlay and compare up to 6 evaluation metrics simultaneously from turn-on.
●Standard CSV Export of Full-Pixel Spectra & Time-Series Summary
Exports both time-series metric summaries and full-pixel spectral data (wavelength, raw counts, Dark, Reference, calibrated spectrum) in standard CSV format with zero proprietary binary lock-in — ready for direct import into Excel, Origin, Python (Pandas / Matplotlib), or MATLAB.
●Automated Stability Report Generation via Bundled Python Script
Use the bundled light-source stability script to automatically configure monitoring bands, run long-term acquisition, compute warm-up convergence time (±1.0% settling time) and peak-to-peak drift rate, and export a formatted Markdown evaluation report with a single command.
![GRANATUS [Analysis + Trend] View showing light source warm-up and long-term drift curves](/images/software/granatus/fig03_granatus_trend_warmup_drift.png)
[Analysis + Trend] View: Emission spectrum on top and multi-trace time-series trend chart ([Δ Change] mode showing warm-up convergence across multiple bands) on bottom
Object Color / Yellowness of Lenses & Films and CCT / CRI of LED Lighting
Compliant with CIE / ISO / ASTM (JIS) standards for transmitted/reflected object color and light source color rendering
Adding the + Colorimetry option enables real-time calculation and graphical plotting of transmitted/reflected object chromaticity and color difference, as well as light source correlated color temperature (CCT) and Color Rendering Index (CRI).
Object Color Mode & Light Source Color Mode
●Object Color Mode (Optical Lenses, Color Filters, Glass, Polymer Films)
Calculates tristimulus values XYZ, chromaticity (xy, u'v'), and CIE L*a*b* / L*C*h° under standard illuminants (D65, D50, A, F2, etc.) and 2°/10° observers in compliance with CIE 15, ISO/CIE 11664-1, 11664-3, 11664-4, 11664-5, 11664-6, and ASTM E313 (JIS Z 8781-1, Z 8781-3, Z 8781-4, Z 8781-5, and Z 8730). Plots target coordinates and CIEDE2000 (ΔE*00) tolerance ellipses on the a*b* plane to visually judge both the magnitude and direction of color shifts, alongside Yellowness Index (YI) and Whiteness Index (WI).
●Light Source Color Mode (White LEDs, Luminaires, Display Backlights)
Complies with CIE 15 and CIE 13.3-1995 (JIS Z 8725 and Z 8726) using Relative Irradiance spectra corrected with standard lamp calibration data. Evaluates Correlated Color Temperature (CCT [K]), deviation from the Planckian locus (Duv), General CRI (Ra), and all 15 Special CRI indices (R1–R15, including saturated red R9) with a 16-bar Munsell color chart and CIE 1931 / 1976 chromaticity diagrams.

Object Color Mode: L*a*b* plane and CIEDE2000 tolerance ellipse contour

Light Source Mode: CRI bar chart (Ra, R1–R15) with Munsell color patches

Light Source Mode: CIE 1931 xy chromaticity diagram with Planckian locus
Quality Assurance Lot Sampling Inspection & Automated A4 HTML Inspection Reports
Barcode-driven recipe selection and single-file A4 HTML inspection reports with lot statistics and spectral overlays
Eliminates manual filename entry, recipe selection mistakes, and spreadsheet transcription errors during incoming and outgoing lot inspections.
Standard 4-Step Inspection Workflow
Automatic Recipe Selection via Barcode Scan
Scanning the barcode or 2D code on a work order automatically selects the corresponding part recipe and sets the lot number. A deferred file-creation guard prevents empty CSV files from being created until the first measurement is recorded.
Hands-Free Measurement Recording via Foot Switch or Shortcut Key
Place the sample and record measurements using a keyboard shortcut or USB foot switch. Built-in interlocks block recording if the system is uncalibrated or if sensor saturation occurs.
Single-Shot Undo & Re-Measurement with Full Audit Trail
If a sample is mispositioned, cancel the last record and re-measure under the same sample number. Canceled records are retained in the CSV file as an audit trail while being automatically excluded from lot statistics.
Automated Generation of A4-Printable HTML Inspection Reports
Closing the lot automatically generates a self-contained HTML inspection report combining summary statistics (Mean, standard deviation σ, Min/Max, yield, process capability Cp / Cpk), an all-sample SVG spectral overlay chart, and trend graphs — ready for direct A4 printing or PDF archiving.
4 Built-In Error-Proofing Interlocks (Poka-Yoke)
●1. Uncalibrated & Sensor Saturation Recording Guard
Automatically blocks metric calculation and lot recording if Dark/Reference calibration has not been performed or if excessive light causes sensor saturation, preventing invalid data from being logged as JUDGE: PASS.
●2. Recipe Edit Lock During Active Lot or Remote Operation
Automatically locks pass/fail criteria and recipe editing after the first sample in a lot is recorded (preventing mid-lot CSV column changes) or during PLC remote control.
●3. Spreadsheet File-Lock Detection & In-Memory Pending Buffer
Even if an operator accidentally leaves the output CSV file open in Excel during lot measurement, GRANATUS safely buffers new records in memory (displaying a pending indicator) and flushes them in batch once Excel is closed.
●4. Interrupted Lot Resume (Smart Resume)
If the software is closed for a shift change or break, you can reload the existing lot CSV, resume recording from the next sample number, and generate a unified HTML inspection report covering all samples.
Quality Audit & Traceability Records
Automatically logs lot number, part number (recipe name), operator name, timestamp per sample, individual metrics and JUDGE: PASS/FAIL results, canceled record history (audit trail), and lot statistics (Mean, σ, Min/Max, yield, Cp / Cpk) in both CSV and HTML report formats.
Experience an Actual A4-Printable 'HTML Inspection Report' in Your Browser
Explore an actual outgoing sampling inspection report for a visible bandpass filter (Lot ID: LOT-BPF550-20261110 / n=10 valid samples + 1 canceled record audit trail due to holder tilt). Inspect the resolution-independent vector SVG spectral overlay, 9-item Cp / Cpk statistical summary, and single-page A4 print/PDF layout via your browser's Print Preview (Ctrl+P).
- ✓Vector SVG spectral overlay (n=10 valid samples + lot mean curve)
- ✓9-metric lot statistics table (Mean, SD σ, Min/Max, Cp / Cpk)
- ✓Seq #5 canceled record audit trail ([F3 Undo] excluded from stats)
- ✓One-click A4 Print / PDF Preview layout
FA Production Line Integration & PLC Automated Inline Inspection
Build PLC-linked inline automated inspection through standard configuration with zero custom software development
Connects directly to production line PLCs over Ethernet to execute externally triggered measurements, pass/fail judgment, and PLC register write-back without custom programming (Inline Edition).
Key FA & PLC Integration Capabilities
●Multi-Protocol Direct PLC Connection
Native support for Mitsubishi Electric MELSEC (SLMP / MC Protocol 3E frame and MX Component), KEYENCE KV Series (SLMP compatible), and standard Modbus/TCP. No OPC server middleware required.
●2-Phase Handshake (Sequence Number Echo-Back) & 32-Bit Scaled Integer Output
Uses deterministic 2-phase handshake control verifying request sequence number (ReqSeq) and completion echo-back (AckSeq = ReqSeq). Floating-point measurement values are scaled by a fixed or custom multiplier into 32-bit signed integers and written in batch to PLC word registers alongside judgment flags.
●Seamless Data Compatibility Between R&D / Lead Plants & Global Factories (JA / EN Bilingual)
Switch the UI and inspection report language between Japanese and English from the settings dialog. Evaluation recipes (recipes.xml) and barcode mapping tables created at your main R&D or lead production site can be deployed directly to overseas English-language lines without file conversion, producing identical CSV column structures.
FA Inline System Architecture (2-phase PLC handshake & cold-standby spare PC failover via spectrometer hardware-key licensing)
Coordinated Measurement with External Instruments: Built-In Local API / AI (MCP) Server
GRANATUS includes a built-in local HTTP server compliant with JSON-RPC 2.0 and MCP (Model Context Protocol) for controlling measurement, analysis, and lot logging from external programs.
While simple time-lapse logging can be performed using the built-in timer logger alone, the local API lets you synchronize GRANATUS with your existing laboratory equipment (motorized stages, environmental chambers, programmable power supplies) to build automated sweep measurement systems in minutes.
No Vendor-Specific SDKs or DLLs Required — Control Instantly from Python, LabVIEW, C#, or PowerShell
No need to integrate vendor-specific SDKs/DLLs or write custom optical calculation code for each spectrometer brand. Simply send standard HTTP requests (JSON) to switch recipes, fetch calibrated spectra and evaluated metrics (OD, cut-WL, color difference), append lot records, and export HTML reports.
Interactive Operation from AI Assistants (Claude Desktop, etc.) & Bundled Sample Scripts
Connect MCP-compatible AI clients for natural-language measurement assistance, or run the Python / PowerShell / TypeScript sample scripts bundled in the installation folder (scripts/) for scheduled logging and light-source stability testing.
Enterprise-Ready Network Security (Localhost Only [Default] / LAN Remote / Completely OFF)
By default, the API server listens exclusively on the internal loopback address (127.0.0.1), blocking access from external networks. Depending on your deployment, you can bind it to a LAN IP address for remote control from an upper-level controller PC, or disable (OFF) the API server completely to comply with factory security policies.
Representative Automated Sweep Scenarios with External Equipment
Automated Angle of Incidence (AOI) Measurement of Optical Filters (Motorized Rotation Stage)
Step the incidence angle on a filter from 0° to 45° while automatically recording transmittance, WL at Target Intensity (YFix) cut wavelengths, and Center WL (CWL) shift at each angle.
Multi-Point In-Plane Uniformity Mapping of Optics & Substrates (Motorized X-Y Stage)
Scan an X-Y stage across coordinates while logging transmittance, Optical Density (OD), and chromaticity (L*a*b*) into a lot to quantify spatial variation.
LED & Laser Diode Current × Temperature Sweep Testing (Programmable Power Supply & Chamber)
Step drive current (e.g., 50 mA to 300 mA) and ambient temperature while recording spectra at each condition, automatically generating a single HTML report with multi-condition overlay spectra and summary statistics upon completion.
* Full API tool specifications and Python script examples for stage/power-supply synchronization are provided in the 'Automated Experiment & Local API / AI Integration Guide' included with the trial and product editions.
Coordinated Sweep Measurement Block Diagram synchronizing external stages, power supplies, and chambers via Local HTTP API / MCP
Implementation Approach Comparison & GRANATUS Advantages
Comparison of Spectral Measurement & Inspection Approaches
Comparison of three typical approaches to building a spectral measurement and inspection environment:
| Comparison Item | Bundled Viewer Software + Spreadsheets | Custom-Developed Software | TAMTEC GRANATUS |
|---|---|---|---|
| Optical Metrics (OD, YFix Cut-WL, Δλ Slope), Colorimetry & CRI | Manual calculation in spreadsheets after CSV export | Requires custom specification & algorithm development | Standard Built-In (Real-time calculation via recipe selection) |
| Lot Sampling Logging, Barcode Recipe Switching & A4 HTML Reports | Not supported (Requires manual entry & transcription) | Requires custom report & barcode integration coding | Standard Built-In (Barcode scan → Record → Auto HTML report) |
| Direct PLC Link (SLMP / Modbus) & Inline Pass/Fail Judgment | Not supported | Requires custom PLC protocol & interlock development | Standard Built-In (Configure PLC register addresses in UI) |
| Future Spectrometer EOL Replacement with Another Vendor's Model | Requires changing software and operating manuals | Requires software modification for the new SDK | No Software Modification Needed (Switch profile & recalibrate) |
| Line Recovery Upon Main PC Failure (Pre-Installed Spare PC) | Varies by vendor and configuration | Often incurs extra license fees or re-activation | Free Pre-Installation on Spare PC (Swap USB cable to recover) |
| Deployment Lead Time | Immediate (* Ongoing daily manual processing overhead) | 3 to 6 Months (Requirements, design & integration testing) | Immediate to a Few Days (30-day free trial available / * Excludes PLC ladder engineering) |
Supported Spectrometer Vendors & Turnkey Hardware + Software Packages
Use Your Existing USB Spectrometers (Multi-Vendor Support)
- Supports USB spectrometers from Ocean Insight, Avantes, and OTO Photonics (models supported by vendor profiles).
- Instant Hardware Verification with Free 'A/D Check Mode': Even before activating a license, you can install the software, connect your spectrometer, and verify live raw spectral waveforms (A/D Raw) and auto-exposure.
- Custom profile creation and connection verification are also available for other spectrometer brands and models — please contact us with your model number.
Need Hardware Too? Turnkey Proposals Including Spectrometer, Light Source & Fixtures
- If you want to inspect films, lenses, or LEDs but are unsure which wavelength range, light source, and optical fiber fixtures to combine, our optical engineers can propose and deliver a complete pre-configured turnkey system including hardware selection, custom fixture design, GRANATUS license, and initial recipes.
Turnkey Optical Measurement Setups (Setup A: Transmittance, OD & Cut-WL / Setup B: Reflectance Object Color & LED CRI)
Main Specifications & System Requirements
| OS & System Requirements | • OS: Windows 10 / Windows 11 (64-bit) • CPU / RAM: Intel Core i5 or higher recommended / 8 GB RAM or more • Display: Full HD (1920 × 1080) or higher recommended (supports dark theme and high-DPI scaling) • Interface: USB 2.0 / 3.0 port (for USB spectrometer connection; optional USB barcode reader / foot switch) |
|---|---|
| Supported Spectrometers & Wavelengths | • Supported Brands: Ocean Insight, Avantes, OTO Photonics, and other USB spectrometers * Can be introduced as software-only for your existing spectrometer, or delivered as a turnkey set with a spectrometer and light source selected for your sample. • Wavelength Range: UV, VIS, and NIR (depends on connected spectrometer; Colorimetry & CRI require 380–780 nm coverage) |
| Calibration & Preprocessing | • Preprocessing: Auto exposure adjustment, temporal averaging, boxcar wavelength smoothing • Intensity Calibration: ① Raw [cnt] / Exposure-normalized [cnt/ms], ② Transmittance & Reflectance [%], ③ Relative Irradiance (standard lamp CSV correction) • Reference Management: Live Dark/Reference acquisition, or fixed Golden Master CSV reference |
| Optical Filter & Spectrum Metrics | • Wavelength Band / Fixed λ: Mean, Min, Max, Trapezoidal Area (supports non-uniform pixel spacing), and Mean-to-OD (noise-canceling optical density) • Characteristic Wavelengths: Wavelength at target intensity (YFix: 0.01 nm linear interpolation), Edge Slope Width Δλ (supports cross-domain [%T] × [OD]), FWHM / Center Wavelength (CWL), Peak / Valley detection (Arithmetic AA & Harmonic HA mean) |
| Time-Series Trend & Continuous Logging | • Interval Timer Logging: 0.1 s to 3600 s interval, up to 100,000 points, real-time CSV disk flush • Trend Plot: Simultaneous tracking of up to 6 evaluation items, toggle between Absolute Value and [Δ Change from Initial Baseline (0)] |
| Pass/Fail, Lot Inspection & Reporting (Inspection / Inline) | • Pass/Fail Judgment: LSL/USL limits per item, overall PASS/FAIL banner, uncalibrated & sensor saturation safety guards • Lot Operations: Product recipe switching via barcode (USB HID / virtual COM), hands-free recording via USB foot switch, last-sample Undo (with audit trail), interrupted lot resume • Report Output: Single-file A4 HTML Inspection Report (Mean, σ, Min, Max, Cp, Cpk, and vector SVG spectrum overlay; printable to PDF) |
| Colorimetry & CRI (+ Colorimetry Option) | • Object Color (CIE 15 / ISO/CIE 11664-1 / 11664-3 / 11664-4 / 11664-5 / 11664-6 / ASTM E313; JIS Z 8781-1 / Z 8781-3 / Z 8781-4 / Z 8781-5 / Z 8730): XYZ, xy, u'v', CIE L*a*b*, L*C*h°, ΔE*ab, CIEDE2000 (ΔE*00) with a*b* tolerance ellipse, Yellowness Index (YI), Whiteness Index (WI) • Light Source Color (CIE 15 / CIE 13.3; JIS Z 8725 / Z 8726): Correlated Color Temperature CCT [K], Duv, General CRI (Ra), Special CRI (R1–R15 including saturated red R9) • Standard Illuminants & Observers: D65, D50, A, C, F2, F7, F11 / 2° and 10° standard observers |
| External Control & Factory Communications | • PLC Communications (Inline): Mitsubishi Electric MELSEC / KEYENCE KV (SLMP 3E frame / MX Component), Modbus/TCP, 2-phase handshake, 32-bit signed integer scaling • Local API: HTTP JSON-RPC 2.0 / MCP (Model Context Protocol) server (Default: 127.0.0.1 localhost only; configurable for LAN IP or completely disabled) • UI & Report Languages: English / Japanese (instant switching; 100% XML recipe compatibility across global factories) |
* Wavelength accuracy, spectral resolution, photometric accuracy, and S/N ratio depend on the hardware specifications of the connected spectrometer, light source, and optical fixtures.
Editions & Standard Pricing
Choose from three base editions (Lab / Inspection / Inline) and the optional Colorimetry add-on (+ Colorimetry) to match your application.
All perpetual licenses include 1 year of complimentary maintenance support (software updates, technical Q&A, and free license transfer in the event of hardware failure).
* Reference prices shown below are standard list prices in Japanese Yen (JPY, excluding tax). For international orders, USD / EUR quotations, proforma/commercial invoices, and procurement through local distributors, resellers, or trading companies are fully supported.
Standard Editions & Model Numbers (Perpetual License per System, Tax Excluded)
GRANATUS Lab
Standard Price (excl. tax)
From 300,000 JPY
SKU: TAMTEC-GRN-LAB
With + Colorimetry (excl. tax)
From 450,000 JPY
SKU: TAMTEC-GRN-LAB-C
Key Use Cases & Features
- Real-time evaluation of optical properties, OD, and FWHM
- Timer-based continuous logging & real-time trend graphs
- Python / MCP automated experiment script integration
Recommended Environment & Licensing
• University, research institute, and corporate R&D laboratories
• Ideal when swapping multiple spectrometers on a single PC (PC Hardware ID bound license)
GRANATUS Inspection
Standard Price (excl. tax)
Contact for Quote
SKU: TAMTEC-GRN-INS
With + Colorimetry (excl. tax)
Contact for Quote
SKU: TAMTEC-GRN-INS-C
Key Use Cases & Features
- All Lab features plus LSL/USL pass/fail judgment (JUDGE: PASS/FAIL)
- Lot sampling logging (foot switch & undo support) and barcode recipe switching
- Automated generation of A4-printable HTML inspection reports
Recommended Environment & Licensing
• Standard inspection terminals for incoming/outgoing QA rooms
• Spectrometer Serial No. bound license allows free pre-installation on spare or offline recipe-editing PCs
GRANATUS Inline
Standard Price (excl. tax)
Contact for Quote
SKU: TAMTEC-GRN-INL
With + Colorimetry (excl. tax)
Contact for Quote
SKU: TAMTEC-GRN-INL-C
Key Use Cases & Features
- All Inspection features plus direct PLC communication (SLMP / MELSEC MX / Modbus TCP)
- FA Remote mode, external trigger synchronization, and PLC word register write-back
Recommended Environment & Licensing
• Integration into automated FA inspection machines and inline production equipment
• Spectrometer Serial No. bound license enables instant line recovery using a pre-configured cold-standby IPC
Options & Related Services (Tax Excluded)
+ Colorimetry Option Add-On (Model: TAMTEC-GRN-OPT-C)
Can be added to any edition at any time (For Lab: +150,000 JPY / For Inspection & Inline: Contact for Quote)
GRANATUS Lab 1-Year Term License (Fixed Term, No Auto-Renewal)
Standalone: From 150,000 JPY / year (TAMTEC-GRN-LAB-1Y) / With + Colorimetry: From 225,000 JPY / year (TAMTEC-GRN-LAB-C-1Y). Ideal for single-fiscal-year academic grants or fixed-duration R&D projects (upgradeable to a perpetual license during the term).
FA Initial Setup & PLC Register Configuration Support Pack (Model: TAMTEC-GRN-SVC-FA)
Engineering support package where our engineers configure initial recipes and verify PLC communication tailored to your spectrometer and register map (Contact for Quote).
Spectrometer Hardware Bundle Discount & Multi-Line Expansion Discount
Special pricing is available when purchasing spectrometers, light sources, and optical fixtures together with GRANATUS or when deploying additional licenses across multiple lines at the same facility.
Annual Maintenance Support Renewal from Year 2 (Optional, Model: TAMTEC-GRN-MNT-1Y)
1 year of maintenance support is included free of charge with every perpetual license. Because standard licenses are perpetual, your installed software version continues to operate without expiration even if you choose not to renew maintenance after Year 1 (software updates and free hardware-failure license transfers apply during active maintenance coverage).
Distributor Procurement & Academic / Public Grant Invoicing
Available via direct purchase or through your preferred scientific/FA equipment distributor using standard TAMTEC- model numbers. We also support institutional procurement procedures for universities and public research institutes.
Feature Comparison Matrix
| Category | Key Features | Lab (From 300,000 JPY) | Inspection (Contact for Quote) | Inline (Contact for Quote) |
|---|---|---|---|---|
| Core Spectroscopy & Calibration | Multi-vendor spectrometer control, auto-exposure, 3 calibration modes (Uncorrected Raw Mode / Relative Ratio [%] / Relative Irradiance), uncalibrated guard lock | Included | Included | Included |
| Optical Evaluation Markers | Wavelength Band / Fixed WL statistics (Mean, integral, Max, Min, SD, CV), Mean then OD (Mean->OD), WL at Target Intensity (YFix), Edge Transition Width (Δλ), 2-WL slope, Peak / Valley Detection (AA/HA), FWHM / Center WL (CWL) | Included | Included | Included |
| Time-Series Logging | Single-shot CSV save, automated timer logging, real-time trend chart (Absolute / Δ Change / Spec %), lot summary CSV export | Included | Included | Included |
| External Script / AI Link | Local MCP / JSON-RPC server (stage/power/chamber sweep integration, Python / PowerShell / C# control, bundled sample scripts) | Included (Measurement & logging) | Included (+ Lot, barcode & HTML report) | Included (+ FA trigger & PLC control) |
| Pass/Fail & Lot Sampling | Per-metric LSL/USL judgment, overall JUDGE: PASS/FAIL badge, lot preparation, manual/foot-switch record, single-shot undo | — (Calculation & logging only) | Included | Included |
| Barcode & Inspection Report | Automatic recipe switching via barcode scan, A4-printable single-file HTML inspection report (statistics, Cp/Cpk, spectral overlay) | — | Included | Included |
| FA & PLC Inline Control | Direct PLC communication (SLMP / MELSEC MX / Modbus TCP), FA Remote mode, external trigger sync & PLC word register write-back | — | — | Included |
| Colorimetry & CRI (+ Colorimetry Option) | + Colorimetry Option (available for all editions): Object color (L*a*b*, L*C*h°, ΔE*00, YI, WI, tolerance ellipse) & Light source color (CCT, Duv, Ra, R1–R15, CIE xy / u'v' diagram) | Optional (+150,000 JPY) | Optional (Contact for Quote) | Optional (Contact for Quote) |
| Standard License Binding | Hardware identification binding method | PC Hardware ID Bound (Swap multiple spectrometers on 1 PC) | Spectrometer Serial No. Bound (Free pre-install on spare PCs) | Spectrometer Serial No. Bound (Free pre-install on spare PCs) |
How to Get Started (30-Day Free Trial License)
We offer a 30-day free trial license unlocking all features (equivalent to Inline + Colorimetry) so you can verify connectivity with your own spectrometer and evaluate optical metrics, color difference, and HTML inspection reports with actual samples.
Even before installing a license file, GRANATUS launches in 'A/D Check Mode' immediately after installation, allowing you to test hardware communication and observe live A/D Raw waveforms.
Contact Us & Receive the Installer
Reach out via our contact form below. We will provide the installer (ZIP) and a 30-day free evaluation license.
Verify Hardware & Evaluate Full Features for 30 Days
Connect your PC and spectrometer to test all capabilities with your actual samples and inspection workflows. Online technical support for setup and recipe creation is available.
Submit License Information (PC ID / Spectrometer Serial No.)
Once you decide to adopt GRANATUS, open [Help] → [About] → [License Info], click [Copy to Clipboard], and email the information to receive your production license file (license.xml). All recipes and calibration data created during the trial carry over without reinstallation.
Frequently Asked Questions (FAQ)
Q.Can I use GRANATUS with third-party USB spectrometers I already own?
Yes. GRANATUS supports USB spectrometers from Ocean Insight, Avantes, and OTO Photonics (models supported by vendor profiles). Please feel free to contact us with your spectrometer manufacturer and model number to confirm compatibility. We can also propose a complete pre-configured hardware + software turnkey package including spectrometer, light source, and fiber fixtures.
Q.Can GRANATUS operate on factory PCs with no internet access (completely offline / closed networks)?
Yes. GRANATUS operates 100% offline. License authentication uses a local digitally signed file (Config/license.xml) that requires no internet communication and never transmits data externally.
Q.How can I extract license request information from a factory PC where USB flash drives are prohibited?
Simply take a photo of the [License Info] dialog on the screen using a smartphone or camera and email the image to us — there is no need to manually transcribe a 64-character hardware ID.
Q.Can I start with the R&D 'Lab' edition and later upgrade to 'Inspection', 'Inline', or the 'Colorimetry Option (+ Colorimetry)'?
Yes. Upgrades between editions are available based on the price difference. Simply replace the license.xml file to unlock higher-tier features while preserving all existing recipes and historical data.
Q.If a production line PC or spectrometer fails, will license re-issuance cause line downtime?
In the Inspection and Inline editions, licenses are bound to the spectrometer's serial number rather than the PC. You can pre-install the software and license file on a spare PC at no extra cost; if the main PC fails, simply plug the spectrometer USB cable into the spare PC for immediate line recovery. If the spectrometer itself requires repair or replacement (changing its serial number), we reissue the license for the new serial number free of charge under your first-year complimentary support or active annual maintenance contract.
Q.Do you support university research grants, purchase orders (payment upon acceptance), or procurement through local distributors or resellers?
Yes. For universities and public research institutes, we issue official quotations, proforma/commercial invoices, and delivery documentation compliant with institutional accounting rules, and offer a 1-Year Term License (from 150,000 JPY/year) ideal for annual research budgets. For corporate and factory customers worldwide, we also support procurement through your designated local distributor, reseller, trading company, or system integrator using standard TAMTEC- SKU codes.
For Distributors & System Integrators
GRANATUS can be offered as a value-added analysis and inspection software option alongside the spectrometers and optical systems you distribute. We support installation on your demonstration units, reseller transactions via standard part numbers, and joint technical proposals for your customers. Please feel free to contact us for partnership inquiries.
* We also continue to provide custom measurement and control software development tailored to specialized hardware and unique inspection requirements.
Request a 30-Day Free Trial, Technical Consultation, or Quotation
Whether you want to check spectrometer compatibility, request a 30-day free trial license or quotation (direct or via distributor),
or consult on sample suitability and turnkey hardware selection, our optical engineers are ready to assist.
* In the contact form, please mention 'GRANATUS Free Trial Request' or your planned spectrometer brand and model (even if undecided).